Owner’s ManualModels4437844379Form# 44126-0120120730©2012 Hunter Fan Co.English7 Day ProgrammableINSTALLATION5 MINUTEM TWT F S S
44126-01 • 07/30/2012©2012 Hunter Fan Company10Setting Day and TimeOnce you install the batteries, the thermostat will prompt you to set the current
44126-01 • 07/30/2012©2012 Hunter Fan Company11Setting Day and TimeDone/HomeMenuBackNextScheduleSaveAwayHomeToday1-2Mon:PMDone/HomeMenuBackNextSched
44126-01 • 07/30/2012©2012 Hunter Fan Company12* The schedule time can be set in 15 minute increments, and remains the same for both Heat and Cool p
44126-01 • 07/30/2012©2012 Hunter Fan Company13Personal Scheduling ChartsDay Away Asleep HomeMonday-FridayStart Time: 8:00amEnd Time: 6:00pmHeat Tem
44126-01 • 07/30/2012©2012 Hunter Fan Company14Setting Your Schedule1. Press the Schedule Button to enter Scheduling mode.2. Use the or button
44126-01 • 07/30/2012©2012 Hunter Fan Company15Setting Your ScheduleDone/HomeMenuBackNextScheduleSaveAwayHomeToday3SunSatFriThuWedTuesMonDone/HomeMe
44126-01 • 07/30/2012©2012 Hunter Fan Company166. Set the temperature for your heating cycle as indicated by the ashing ”Heat to” icon on your scr
44126-01 • 07/30/2012©2012 Hunter Fan Company17Setting Your ScheduleDone/HomeMenuBackNextScheduleSaveAwayHomeToday6MonAwayAsleepAt HomeoCool totoAM:
44126-01 • 07/30/2012©2012 Hunter Fan Company18Setting Your Schedule10. The day select screen will now show “Copy Day” and ask you if you wish to c
44126-01 • 07/30/2012©2012 Hunter Fan Company19Setting Your ScheduleDone/HomeMenuBackNextScheduleSaveAwayHomeToday10MonCopy DayDone/HomeMenuBackNext
44126-01 • 07/30/2012©2012 Hunter Fan Company2At A GlanceKnow Your ermostat � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �
44126-01 • 07/30/2012©2012 Hunter Fan Company20Temporary Temperature ChangeWith Temporary Temperature Change you have the ability to alter the tempe
44126-01 • 07/30/2012©2012 Hunter Fan Company21Temporary Schedule ChangeDone/HomeMenuBackNextScheduleSaveAwayHomeToday1MonAt HomeoAutooHeat toEnergy
44126-01 • 07/30/2012©2012 Hunter Fan Company22Turning Off SchedulingTo turn off your schedule and have the thermostat permanently set to one tempera
44126-01 • 07/30/2012©2012 Hunter Fan Company23Turning Off SchedulingDone/HomeMenuBackNextScheduleSaveAwayHomeToday1MonAt HomeoAutoo:AMHeat toEnergy
44126-01 • 07/30/2012©2012 Hunter Fan Company24Home TodayThe Home Today feature allows you to override your schedule for 1 day. It can be used for e
44126-01 • 07/30/2012©2012 Hunter Fan Company25Home TodayDone/HomeMenuBackNextScheduleSaveAwayHomeToday2Heat toEnergy Savings:Good Best!Done/HomeMen
44126-01 • 07/30/2012©2012 Hunter Fan Company26Save AwayThe Save Away feature allows you to set a lower or higher temperature for the time you will
44126-01 • 07/30/2012©2012 Hunter Fan Company27Done/HomeMenuBackNextScheduleSaveAwayHomeToday2oHeat toHoursEnergy Savings:Good Best!Done/HomeMenuBac
44126-01 • 07/30/2012©2012 Hunter Fan Company28AlertsThis chapter will outline the various alerts the thermostat will report to you and how to respo
44126-01 • 07/30/2012©2012 Hunter Fan Company29AlertsDone/HomeMenuBackNextScheduleSaveAwayHomeToday1b1aDone/HomeMenuBackNextScheduleSaveAwayHomeToda
44126-01 • 07/30/2012©2012 Hunter Fan Company3Your thermostat has been pre-programmed from the factory with no programming necessary. We recommend u
44126-01 • 07/30/2012©2012 Hunter Fan Company303. Auxiliary Heat: On multi-stage heat pumps this alert indicates your second stage heat is running.
44126-01 • 07/30/2012©2012 Hunter Fan Company31AlertsDone/HomeMenuBackNextScheduleSaveAwayHomeToday3MonAt HomeoAutooPMHeat toEnergy Savings:Good Bes
44126-01 • 07/30/2012©2012 Hunter Fan Company32Menu OptionsUnder your menu options you have the ability to reset your lter counter, change your day
44126-01 • 07/30/2012©2012 Hunter Fan Company33Menu OptionsDone/HomeMenuBackNextScheduleSaveAwayHomeToday2Reset FilterSet Day/TimeSpan 1Span 2Temp F
44126-01 • 07/30/2012©2012 Hunter Fan Company345. SPAN 1: The next menu option is to set your thermostats primary span. Use the or buttons to a
44126-01 • 07/30/2012©2012 Hunter Fan Company35Menu OptionsDone/HomeMenuBackNextScheduleSaveAwayHomeToday5oSpan 1Done/HomeMenuBackNextScheduleSaveAw
44126-01 • 07/30/2012©2012 Hunter Fan Company36Menu Options1. LOCK/UNLOCK: Allows you to lock the thermostat so random keypress’ will not change yo
44126-01 • 07/30/2012©2012 Hunter Fan Company37Menu OptionsDone/HomeMenuBackNextScheduleSaveAwayHomeToday2MonAt HomeoAutoo:PMHeat toLockEnergy Savin
44126-01 • 07/30/2012©2012 Hunter Fan Company38Energy Saver BarThe Energy Saver Bar indicates estimated energy savings. The preset schedules in the
44126-01 • 07/30/2012©2012 Hunter Fan Company39Energy Saver BarDone/HomeMenuBackNextScheduleSaveAwayHomeToday1MonAt HomeoAutooPM:Heat toEnergy Savin
44126-01 • 07/30/2012©2012 Hunter Fan Company41. Enters Schedule Setup for altering scheduled programs.2. Sets the Home Today feature for when you
44126-01 • 07/30/2012©2012 Hunter Fan Company40Additional Features There is no need to stand at the wall where the thermostat is mounted while progr
44126-01 • 07/30/2012©2012 Hunter Fan Company41Troubleshooting and SupportProblem:No display.Solution: 1. Check battery position and battery life.Pr
44126-01 • 07/30/2012©2012 Hunter Fan Company42Problem:Fan runs continuously.Solution: 1. Check fan setting to see if it is set to on. 2. Move HG/HE
44126-01 • 07/30/2012©2012 Hunter Fan Company43Technical SupportIf you need any assistance with installion or setup of your new Hunter Thermostat, p
44126-01 • 07/30/2012©2012 Hunter Fan Company441 Year GuaranteeHunter Fan CompanyThermostatsLIMITED WARRANTYThe Hunter Fan Company warrants your Hun
44126-01 • 07/30/2012©2012 Hunter Fan Company45Suite 400, Memphis, TN 38016. You will be responsible for all insurance and freight or other transpor
44126-01 • 07/30/2012©2012 Hunter Fan Company5Know Your ermostat1853276119106Done/Home4
44126-01 • 07/30/2012©2012 Hunter Fan Company61. Holds 2 “AA” Batteries. 2. HE/HG Switch - allows you to set your furnace to Gas/Oil or Electric,
44126-01 • 07/30/2012©2012 Hunter Fan Company7132Know Your ermostat
44126-01 • 07/30/2012©2012 Hunter Fan Company81. Shows the current day of the week or weekend.2. Indicates the thermostat is running in schedule m
44126-01 • 07/30/2012©2012 Hunter Fan Company9Know Your ermostato:At HomeAutoPMCheck H.P.!HoursAux Em.Energy Savings:GoodBest!LockMonFilterHeat toC